Pneumatic ultra-thin ball valve (also known as pneumatic clamp ball valve) is the introduction of Italian technology for the localization of the design and the development of a new generation of ultra-short flange distance ball valves, is composed of a single (double) action piston type pneumatic actuator and ultra-thin ball valves. Pneumatic ultra-thin ball valve can be equipped with a valve positioner input control signal (4-20mADC or 1-5VDC) to control the operation of the gas source. Can also be equipped with travel limit switches, solenoid valves, pressure reducing valves and 0.4 ~ 0.7MPa gas source can be realized switching operation, and send out two pairs of passive contact signals to indicate the valve switch. Pneumatic ultra-thin ball valve (pneumatic clamp ball valve) ball core channel shape rectangular, V-shaped and O-shaped. This series of products has a compact structure, small size, light weight, easy to install and so on. Therefore, pneumatic ultra-thin ball valve (pneumatic ball valve) is widely used in petroleum, chemical, metallurgy, power station, light industry and other fields, oil, water, gas and pulp or fibrous fluid for automatic adjustment or cut off control.
Pictures of pneumatic ultra-thin ball valves
Third, the main technical parameters of pneumatic ultra-thin ball valve
Q671F pneumatic ultra-thin ball valve (clamp type) | Q671F pneumatic ultra-thin ball valve (flange type) |
1、Valve Body
Valve body form | Straight-through cast ultra-short valves |
Nominal diameter | DN15~150mm |
Nominal pressure | National standard PN1.6, 2.5, 4.0, 6.4 MPa; American standard ANSI 150, 300LB; Japanese standard JIS 10, 20, 30K |
Flange Standard | JIS、ANSI、GB、JB、HGet al. (and other authors) |
Connection form | Flange Type, Clamping Type |
Gland type | Nut compression type |
sealing packing | V-type polytetrafluoroethylene packing, flexible graphite packing, etc. |
Spool type | O-Ball Spool |
Flow Rate Characteristics | Approximate fast-opening type |
2. Actuator
Actuator Model | GT、SR、ST、AT、AWSeries Single and Double Acting Pneumatic Actuator |
Supply pressure | 0.4~0.7MPa |
air interface | G1/4"、G1/8"、G3/8"、G1/2" |
environmental temperature | -20~+90℃ |
Forms of action | Single-acting actuators: Air shut-off (B) - valve position open on loss of air (FO); Air open (K) - valve position closed on loss of air (FC). Double-acting actuators: Air shut-off (B) - hold on loss of air (FL); Air open (K) - hold on loss of air (FL). ) |
Accessories available | Positioners, solenoid valves, air filtration reducers, holding valves, travel switches, valve position transmitters, handwheel mechanisms, etc. |
3. Pneumatic ultra-thin ball valve Main performance indicators
Nominal diameter DN(mm) | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
Allowable Differential Pressure(MPa) | ≤Nominal pressure | |||||||||||||
Range of action | 0~90° | |||||||||||||
leakageQ | According to GB/T4213-92, less than 0.01% of rated KV (soft seal for zero leakage) | |||||||||||||
fundamental error | With positioner: less than full travel±2% | |||||||||||||
return differential (e.g. of farmland) | With positioner: less than full travel2% |
4. Pneumatic ultra-thin ball valve Main performance specifications
test pressure(MPa) | Nominal pressure(MPa) | pressure level(class) | JIS(K) | |||||
1.6 | 2.5 | 4.0 | 6.4 | 150 | 300 | 10K | 20K | |
Strength test | 2.4 | 3.75 | 6.0 | 9.6 | 3.0 | 7.5 | 2.4 | 3.8 |
Sealing test | 1.76 | 2.75 | 4.4 | 7.04 | 2.2 | 5.5 | 1.5 | 2.8 |
air tightness test | 0.5~0.7MPa |
Pneumatic ultra-thin ball valve (also known as pneumatic clamp ball valve) is the introduction of Italian technology for the localization of the design and the development of a new generation of ultra-short flange distance ball valves, is composed of a single (double) action piston type pneumatic actuator and ultra-thin ball valves. Pneumatic ultra-thin ball valve can be equipped with a valve positioner input control signal (4-20mADC or 1-5VDC) to control the operation of the gas source. Can also be equipped with travel limit switches, solenoid valves, pressure reducing valves and 0.4 ~ 0.7MPa gas source can be realized switching operation, and send out two pairs of passive contact signals to indicate the valve switch. Pneumatic ultra-thin ball valve (pneumatic clamp ball valve) ball core channel shape rectangular, V-shaped and O-shaped. This series of products has a compact structure, small size, light weight, easy to install and so on. Therefore, pneumatic ultra-thin ball valve (pneumatic ball valve) is widely used in petroleum, chemical, metallurgy, power station, light industry and other fields, oil, water, gas and pulp or fibrous fluid for automatic adjustment or cut off control.
Pictures of pneumatic ultra-thin ball valves
Third, the main technical parameters of pneumatic ultra-thin ball valve
Q671F pneumatic ultra-thin ball valve (clamp type) | Q671F pneumatic ultra-thin ball valve (flange type) |
1、Valve Body
Valve body form | Straight-through cast ultra-short valves |
Nominal diameter | DN15~150mm |
Nominal pressure | National standard PN1.6, 2.5, 4.0, 6.4 MPa; American standard ANSI 150, 300LB; Japanese standard JIS 10, 20, 30K |
Flange Standard | JIS、ANSI、GB、JB、HGet al. (and other authors) |
Connection form | Flange Type, Clamping Type |
Gland type | Nut compression type |
sealing packing | V-type polytetrafluoroethylene packing, flexible graphite packing, etc. |
Spool type | O-Ball Spool |
Flow Rate Characteristics | Approximate fast-opening type |
2. Actuator
Actuator Model | GT、SR、ST、AT、AWSeries Single and Double Acting Pneumatic Actuator |
Supply pressure | 0.4~0.7MPa |
air interface | G1/4"、G1/8"、G3/8"、G1/2" |
environmental temperature | -20~+90℃ |
Forms of action | Single-acting actuators: Air shut-off (B) - valve position open on loss of air (FO); Air open (K) - valve position closed on loss of air (FC). Double-acting actuators: Air shut-off (B) - hold on loss of air (FL); Air open (K) - hold on loss of air (FL). ) |
Accessories available | Positioners, solenoid valves, air filtration reducers, holding valves, travel switches, valve position transmitters, handwheel mechanisms, etc. |
3. Pneumatic ultra-thin ball valve Main performance indicators
Nominal diameter DN(mm) | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
Allowable Differential Pressure(MPa) | ≤Nominal pressure | |||||||||||||
Range of action | 0~90° | |||||||||||||
leakageQ | According to GB/T4213-92, less than 0.01% of rated KV (soft seal for zero leakage) | |||||||||||||
fundamental error | With positioner: less than full travel±2% | |||||||||||||
return differential (e.g. of farmland) | With positioner: less than full travel2% |
4. Pneumatic ultra-thin ball valve Main performance specifications
test pressure(MPa) | Nominal pressure(MPa) | pressure level(class) | JIS(K) | |||||
1.6 | 2.5 | 4.0 | 6.4 | 150 | 300 | 10K | 20K | |
Strength test | 2.4 | 3.75 | 6.0 | 9.6 | 3.0 | 7.5 | 2.4 | 3.8 |
Sealing test | 1.76 | 2.75 | 4.4 | 7.04 | 2.2 | 5.5 | 1.5 | 2.8 |
air tightness test | 0.5~0.7MPa |
Pneumatic Ultra-thin Ball Valve Main Outline
Pneumatic ultra-thin ball valve Main connection size
Nominal diameter DN(mm) | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 |
L | 108 | 112 | 114 | 127 | 140 | 140 | 152 | 165 | 178 | 190 | 216 |
H | 112 | 115 | 120 | 140 | 170 | 180 | 210 | 240 | 290 | 320 | 350 |
D | 165 | 185 | 200 | 220 | 250 | 285 | 340 | 405 | 460 | 520 | 580 |
D1 | 125 | 145 | 160 | 180 | 210 | 240 | 295 | 355 | 410 | 470 | 525 |
D2 | 46 | 56 | 65 | 76 | 84 | 99 | 118 | 132 | 156 | 184 | 211 |
A | Depends on the valve pressure size. Configuration of the actuator is different, and the external dimensions are also different. This can be viewed on the Pneumatic Actuators page. |
Pneumatic Ultra-thin Ball Valve Main Outline
Pneumatic ultra-thin ball valve Main connection size
Nominal diameter DN(mm) | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 |
L | 108 | 112 | 114 | 127 | 140 | 140 | 152 | 165 | 178 | 190 | 216 |
H | 112 | 115 | 120 | 140 | 170 | 180 | 210 | 240 | 290 | 320 | 350 |
D | 165 | 185 | 200 | 220 | 250 | 285 | 340 | 405 | 460 | 520 | 580 |
D1 | 125 | 145 | 160 | 180 | 210 | 240 | 295 | 355 | 410 | 470 | 525 |
D2 | 46 | 56 | 65 | 76 | 84 | 99 | 118 | 132 | 156 | 184 | 211 |
A | Depends on the valve pressure size. Configuration of the actuator is different, and the external dimensions are also different. This can be viewed on the Pneumatic Actuators page. |