SD series hand filter, composed of 304 stainless steel brush and stainless steel components. The part passes through the filter cover, and the brush device is installed inside the stainless steel filter screen. A simple handle is installed outside the filter cover to remove the micro particles from the filter screen and then discharge, and the water flow is not interrupted during the brushing process. No need to stop and remove the filter to clean the filter, the shell is high quality carbon steel simplified.
1. Determine the following parameters: maximum working flow or import and export pipe diameter DN, maximum work, pressure P, working temperature, filtration accuracy.
2. Determine the structure form according to the site installation position.
3. Determine the relevant materials: filter material, shell material.
4. Determine the filter model number.
The hand brush filter can be installed horizontally or vertically, but the direction of the water flow and the direction of the shell arrow should be consistent, and the direction of the water flow is required from the top down. When the pressure difference between the inlet and outlet pressure reaches 0.04MPa, it is necessary to open the sewage discharge valve and gently turn the handle to brush the filter screen manually until the effluent quality of the sewage outlet stops brushing and discharging. The whole sewage discharge process system can operate normally without shutdown.
working pressure | crushing | working temperature | Filter essence should be |
≤1.0MPa | 60.015MPa | ≤150℃ | d=1.2mm |
Others: overcompliance accuracy and size can be customized according to user requirements, and the flange connection size is 3B-9119.8-88.
model | A | B | C | D | E |
SD SF2 | 460 | 1190 | 1750 | 465 | 228 |
SD SF4 | 460 | 1210 | 1770 | 465 | 228 |
SD SF6 | 620 | 1740 | 2800 | 470 | 235 |
SD SF8 | 800 | 1840 | 2900 | 545 | 308 |
model | Import and export parameters | Sewage outlet parameters | H | S1 | S2 | rate of flow (T/h) | weight | |||
π | in | D1 | D2 | D3 | (Kg) | |||||
SD-2Y | 50 | 2 | Φ150 | Φ240 | Φ285 | 517 | 300 | 225 | 19 | 80 |
SD-2.5Y | 65 | 2.5 | Φ150 | Φ240 | Φ285 | 517 | 300 | 225 | 28 | 100 |
SD-3Y | 80 | 3 | Φ150 | Φ240 | Φ285 | 537 | 300 | 225 | 50 | 130 |
SD-4Y | 100 | 4 | Φ207 | Φ295 | Φ340 | 587 | 300 | 225 | 80 | 150 |
SD-5Y | 125 | 5 | Φ260 | Φ350 | Φ395 | 630 | 300 | 285 | 125 | 180 |
SD-6Y | 150 | 6 | Φ309 | Φ400 | Φ445 | 641 | 300 | 311 | 180 | 230 |
SD-8Y | 200 | 8 | Φ367 | Φ460 | Φ505 | 823 | 398 | 340 | 320 | 280 |
SD-10Y | 250 | 10 | Φ406 | Φ515 | Φ565 | 975 | 423 | 365 | 490 | 320 |
SD-12Y | 300 | 12 | Φ406 | Φ515 | Φ565 | 1000 | 438 | 365 | 710 | 380 |
SD-14Y | 350 | 14 | Φ460 | Φ565 | Φ615 | 1068 | 463 | 395 | 970 | 450 |
SD series hand filter, composed of 304 stainless steel brush and stainless steel components. The part passes through the filter cover, and the brush device is installed inside the stainless steel filter screen. A simple handle is installed outside the filter cover to remove the micro particles from the filter screen and then discharge, and the water flow is not interrupted during the brushing process. No need to stop and remove the filter to clean the filter, the shell is high quality carbon steel simplified.
1. Determine the following parameters: maximum working flow or import and export pipe diameter DN, maximum work, pressure P, working temperature, filtration accuracy.
2. Determine the structure form according to the site installation position.
3. Determine the relevant materials: filter material, shell material.
4. Determine the filter model number.
The hand brush filter can be installed horizontally or vertically, but the direction of the water flow and the direction of the shell arrow should be consistent, and the direction of the water flow is required from the top down. When the pressure difference between the inlet and outlet pressure reaches 0.04MPa, it is necessary to open the sewage discharge valve and gently turn the handle to brush the filter screen manually until the effluent quality of the sewage outlet stops brushing and discharging. The whole sewage discharge process system can operate normally without shutdown.
working pressure | crushing | working temperature | Filter essence should be |
≤1.0MPa | 60.015MPa | ≤150℃ | d=1.2mm |
Others: overcompliance accuracy and size can be customized according to user requirements, and the flange connection size is 3B-9119.8-88.
model | A | B | C | D | E |
SD SF2 | 460 | 1190 | 1750 | 465 | 228 |
SD SF4 | 460 | 1210 | 1770 | 465 | 228 |
SD SF6 | 620 | 1740 | 2800 | 470 | 235 |
SD SF8 | 800 | 1840 | 2900 | 545 | 308 |
model | Import and export parameters | Sewage outlet parameters | H | S1 | S2 | rate of flow (T/h) | weight | |||
π | in | D1 | D2 | D3 | (Kg) | |||||
SD-2Y | 50 | 2 | Φ150 | Φ240 | Φ285 | 517 | 300 | 225 | 19 | 80 |
SD-2.5Y | 65 | 2.5 | Φ150 | Φ240 | Φ285 | 517 | 300 | 225 | 28 | 100 |
SD-3Y | 80 | 3 | Φ150 | Φ240 | Φ285 | 537 | 300 | 225 | 50 | 130 |
SD-4Y | 100 | 4 | Φ207 | Φ295 | Φ340 | 587 | 300 | 225 | 80 | 150 |
SD-5Y | 125 | 5 | Φ260 | Φ350 | Φ395 | 630 | 300 | 285 | 125 | 180 |
SD-6Y | 150 | 6 | Φ309 | Φ400 | Φ445 | 641 | 300 | 311 | 180 | 230 |
SD-8Y | 200 | 8 | Φ367 | Φ460 | Φ505 | 823 | 398 | 340 | 320 | 280 |
SD-10Y | 250 | 10 | Φ406 | Φ515 | Φ565 | 975 | 423 | 365 | 490 | 320 |
SD-12Y | 300 | 12 | Φ406 | Φ515 | Φ565 | 1000 | 438 | 365 | 710 | 380 |
SD-14Y | 350 | 14 | Φ460 | Φ565 | Φ615 | 1068 | 463 | 395 | 970 | 450 |